compli 525/4 BW
JP50093Mechanical data | |
---|---|
Pump | Vertical single-stage |
Free passage | 70 mm |
Pressure pipe | DN 100 |
Bearing | Ball bearings, grease-lubricated |
Oil chamber | No |
Impeller | Vortex impeller, GFK |
Motor housing | Grey cast iron |
Pump housing | Grey cast iron |
Submersible | Yes |
Pressure outlet | DN 80 |
Tank capacity | 117 l |
Weight | 79 kg |
Electrical data | |
---|---|
Voltage | 3/N/PE~400 V |
Motor rating P1 | 3 kW |
Motor rating P2 | 2.2 kW |
Current | 5.1 A |
Power line | 4m H07RN-F |
Wires | 6G1,5 |
Type of enclosure | IP 68 |
Insulation class | F |
Winding thermostat | Yes |
Plug | CEE-16A |

Performance | ||||||
---|---|---|---|---|---|---|
Delivery head H [m] | 5 | 6 | 7 | 8 | 9 | 10 |
Flow rate Q [m³/h] | 56 | 49 | 42 | 32 | 22 | 13 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.



All types have DN 80 / PN 10 connecting flange, however with pipe socket DN 100. For this reason, a non-return valve for the pressure pipe need to be chosen for DN 80 only in case of direct erection. The ownstream pressure pipe is connected to DN 100 by an elastic connection. Sewage lifting stations are to be used for the transport of faecal matter and domestic wastewater in building drainage systems as described in German standard DIN 1986 T3. In keeping with the stipulations of German / European standard EN 12056-4 they have to be mounted with collecting tanks inside building permitting a free space of 60 cm for operation and repair. The pressure pipe has to be passed above the locally defined backpressure level and a non-return valve tested in keeping with German / European standard 12050-4 has to be mounted. In keeping with German / European standard 12056 the ventilation pipe has to be passed up to the roof. EN 12056 paragraph 5.1 In applications where the waste-water inlet must not be interrupted a double system has to be installed.
Mechanical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Inlet gate valve PVC | ||||||
with two pipe sockets, DN 100, PN1 | 360x295 (HxW) | JP28297 | ||||
with two pipe sockets, DN 150, PN2.5 | 660x450 (HxW) | JP28591 | ||||
Sluice valve | ||||||
DN 80, PN 10, EN 1171 | 315x180 (HxB) | JP00639 | ||||
Hand diaphragm pump | ||||||
for emergency purposes (up to Hgeo 15 m) | 640x1½” (HxD) | JP00255 | ||||
Stop valve | ||||||
brass, 1½“ (DN 40), PN 16 | 125x60 (HxB) | JP44786 | ||||
Elastic connection | ||||||
+ Hose band clamps, 1½“ (DN 40), PN 4 | 120x50 (HxD) | JP50902 | ||||
Adapter ring | ||||||
DN 100-DN 80 SML | JP50174 | |||||
Closing set | ||||||
DN 150, required for lateral connection | JP43156 |
Electrical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Rechargeable battery | ||||||
9 V, for mains independent alarm | JP44850 | |||||
Smart Home | ||||||
FTJP radio transmitter | JP47209 |