UV 620-3
JP47339Mechanical data | |
---|---|
Pump | Vertical single-stage |
Free passage | 10 mm |
Bearing | Ball bearings, grease-lubricated |
Seal on motor side | Mechanical seal |
Oil chamber | Yes |
Seal on medium side | SiC mechanical seal |
Run dry protection | Yes |
Submersible | Yes |
Pressure outlet | IG 2" |
Weight | 23 kg |
Electrical data | |
---|---|
Ciruit | Without level control |
Voltage | 3/PE~400 V |
Motor rating P1 | 2.38 kW |
Motor rating P2 | 1.95 kW |
Current | 4.6 A |
Power line | 10m H07RN8-F |
Wires | 4G1,0 |
Type of enclosure | IP 68 |
Insulation class | F |
Winding thermostat | Yes |
Motor protection | on request |
Plug | Without |

Performance | |||||||
---|---|---|---|---|---|---|---|
Delivery head H [m] | 6 | 8 | 10 | 12 | 14 | 16 | 18 |
Flow rate Q [m³/h] | 37 | 34 | 32 | 28 | 24 | 18 | 5 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.



Single unit 2" with GR 50: sump area min. 40x70 cm
Single unit 2" without GR: sump area min. 40x50 cm
Duplex unit 2" with GR 50: sump area min. 70x70 cm
Duplex unit 2" without GR: sump area min. 50x70 cm
In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.
In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.
Suspend control unit in a dry room
Mechanical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Swing-type check valve | ||||||
R50 EN 12050-4 | 2“ (DN 50), PN 4 | 150x120 (HxB) | JP00326 | |||
Ball-type check valve | ||||||
K50 EN 12050-4 | 2“ (DN 50), PN 6 | 185x155 (HxB) | JP44782 | |||
Stop valve | ||||||
brass, 2“ (DN 50), PN 16 | 140x70 (HxB) | JP44787 | ||||
Elastic connection | ||||||
+ Hose band clamps, 2“ (DN 50), PN 4 | 150x63 (HxD) | JP50903 | ||||
Hose coupling | ||||||
Coupling Storz C | 2" male thread | JP50217 | ||||
Coupling wrench | JP25708 | |||||
Pressure hose | ||||||
12,5 m, synthetic, with coupling Storz C, Ø 38 mm | JP50298 | |||||
15 m, synthetic, with coupling Storz C, Ø 52 mm | JP00336 | |||||
Chain | ||||||
certified, 2.5 m, 320 kg, 5 rings (EN 818 mod.) | JP45901 | |||||
certified, 5.0 m, 320 kg, 8 rings (EN 818 mod.) | JP45902 | |||||
certified, 7.5 m, 320 kg, 11 rings (EN 818 mod.) | JP47365 | |||||
Shackle, certified, 630 kg, stainless steel | JP45904 | |||||
Guide rail system | ||||||
GR 50 | JP25593 | |||||
Securing lever | UV 600 | JP49171 |
Electrical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Alarm unit | ||||||
AG10 | subm. ball contact switch, mains dependent, potential-free contact, 9.5 m cable | JP44892 | ||||
Control for single units | ||||||
Control unit 1-46 | JP47990 | |||||
Control unit AD 46 | JP14353 | |||||
Control for duplex units | ||||||
Control unit HIGHLOGO 2-46 | 400 V | JP47999 | ||||
Control unit BD 46 | 400 V, for pumps US 251-253, UV 620-3, UV 625-3 | JP45739 | ||||
Level control | ||||||
Subm. switch pack AmG | 2 subm. ball contact switch with 9.5 m and counterweight | JP16719 | ||||
Subm. switch pack BmG | 3 subm. ball contact switch with 9.5 m and counterweight | JP16726 | ||||
Protective motor plug | ||||||
CEE motor protection 4.5-6.3 A | 400 V with level control | JP09726 | ||||
Rechargeable battery | ||||||
9 V, for mains independent alarm | JP44850 |