US 105 D
JP09408Mechanical data | |
---|---|
Pump | Vertical single-stage |
Free passage | 50 mm |
Bearing | Ball bearings, grease-lubricated |
Seal on motor side | Duplex rotary shaft seals |
Oil chamber | Yes |
Seal on medium side | SiC mechanical seal |
Run dry protection | Yes |
Impeller | Vortex impeller, GFK |
Submersible | Yes |
Pressure outlet | IG 2" |
Weight | 15.1 kg |
Electrical data | |
---|---|
Ciruit | Without level control |
Voltage | 3/PE~400 V |
Motor rating P1 | 1.36 kW |
Motor rating P2 | 1.06 kW |
Current | 2.4 A |
Power line | 10m H07RN-F |
Wires | 4G1,0 |
Type of enclosure | IP 68 |
Insulation class | B |
Winding thermostat | Yes |
Motor protection | Integrated |
Plug | CEE |

Performance | |||||||||
---|---|---|---|---|---|---|---|---|---|
Delivery head H [m] | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
Flow rate Q [m³/h] | 29 | 26 | 23 | 20 | 17 | 14 | 11 | 8 | 4 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.
VDE/GS-Certification for US 75 E/ES, US 105 E/ES




Single unit 2" with GR 50 S: sump area min. 40x65 cm
Single unit 2" without GR: sump area min. 40x50 cm
Duplex unit 2" with GR 50 S: sump area min. 65x70 cm
Duplex unit 2" without GR: sump area min. 50x70 cm
In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.
In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.
Suspend control unit in a dry room
Mechanical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Swing-type check valve | ||||||
R50 EN 12050-4 | 2“ (DN 50), PN 4 | 150x120 (HxB) | JP00326 | |||
Ball-type check valve | ||||||
K50 EN 12050-4 | 2“ (DN 50), PN 6 | 185x155 (HxB) | JP44782 | |||
Stop valve | ||||||
brass, 2“ (DN 50), PN 16 | 140x70 (HxB) | JP44787 | ||||
Elastic connection | ||||||
+ Hose band clamps, 2“ (DN 50), PN 4 | 150x63 (HxD) | JP50903 | ||||
Elbow | ||||||
2“ | JP44771 | |||||
Chain | ||||||
certified, 2.5 m, 320 kg, 5 rings (EN 818 mod.) | JP45901 | |||||
certified, 5.0 m, 320 kg, 8 rings (EN 818 mod.) | JP45902 | |||||
certified, 7.5 m, 320 kg, 11 rings (EN 818 mod.) | JP47365 | |||||
Webbing | ||||||
with shackle | JP45168 | |||||
Guide rail system | ||||||
GR 50 | JP25593 | |||||
Securing lever | US 75-155 | JP41024 | ||||
Bases | ||||||
stainless steel, 50 mm free passage | JP40632 |
Electrical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Washing machine stop | ||||||
AW3 | subm. ball contact switch, mains dependent, 3 m cable | JP44895 | ||||
AWO | for alarm forwarding in case of several washing machines | JP44899 | ||||
Control for duplex units | ||||||
Control unit HIGHLOGO 2-00 | 400 V | JP47997 | ||||
Control unit BD 00 | 400 V, for pumps U6, US 62-105, UV 300 | JP45993 | ||||
Level control | ||||||
Subm. switch pack B | 3 subm. ball contact switch with 9.5 m and fixing devices | JP16725 | ||||
Subm. switch pack BmG | 3 subm. ball contact switch with 9.5 m and counterweight | JP16726 | ||||
Rechargeable battery | ||||||
9 V, for mains independent alarm | JP44850 | |||||
Seal leak detector | ||||||
DKG (für die Ölkammer) | JP44900 | |||||
Smart Home | ||||||
FTJP radio transmitter | JP47209 |